Phillips, Frank; Crowley, Jane; Warburton, Samantha; Staniforth, Karren; Parra-Blanco, Adolfo; Gordon, George S D
Air filtration mitigates aerosol levels both during and after endoscopy procedures Journal Article
In: DEN Open, vol. 3, no. 1, pp. e231, 2023.
Abstract | Tags: aerosols, air conditioning, COVID-19, endoscopy, infection control
@article{Phillips2023-qi,
title = {Air filtration mitigates aerosol levels both during and after
endoscopy procedures},
author = {Frank Phillips and Jane Crowley and Samantha Warburton and Karren Staniforth and Adolfo Parra-Blanco and George S D Gordon},
year = {2023},
date = {2023-04-01},
journal = {DEN Open},
volume = {3},
number = {1},
pages = {e231},
publisher = {Wiley},
abstract = {Objectives: Upper gastrointestinal endoscopies are
aerosol-generating procedures, increasing the risk of spreading
airborne pathogens. We aim to quantify the mitigation of
airborne particles via improved ventilation, specifically
laminar flow theatres and portable high-efficiency particulate
air (HEPA) filters, during and after upper gastrointestinal
endoscopies. Methods: This observational study included patients
undergoing routine upper gastrointestinal endoscopy in a
standard endoscopy room with 15-17 air changes per hour, a
standard endoscopy room with a portable HEPA filtration unit,
and a laminar flow theatre with 300 air changes per hour. A
particle counter (diameter range 0.3 μm-25 μm) took
measurements 10 cm from the mouth. Three analyses were
performed: whole procedure particle counts, event-based counts,
and air clearance estimation using post-procedure counts.
Results: Compared to a standard endoscopy room, for whole
procedures we observe a 28.5x reduction in particle counts in
laminar flow (p 5 μm for oral extubation (12.2x, p \< 0.01),
reduction in particles \<5 μm for coughing/gagging (6.9x, p \<
0.05), and reduction for all sizes in anesthetic throat spray
(8.4x, p \< 0.01) but no significant effect of HEPA filtration.
However, we find that in the fallow period between procedures
HEPA filtration reduces particle clearance times by 40%.
Conclusions: Laminar flow theatres are highly effective at
dispersing aerosols immediately after production and should be
considered for high-risk cases where patients are actively
infectious or the supply of personal protective equipment is
limited. Portable HEPA filers can safely reduce the fallow time
between procedures by 40%.},
keywords = {aerosols, air conditioning, COVID-19, endoscopy, infection control},
pubstate = {published},
tppubtype = {article}
}