Liu, Liangliang; Morgan, Stephen P; Correia, Ricardo; Korposh, Serhiy
A single-film fiber optical sensor for simultaneous measurement of carbon dioxide and relative humidity Journal Article
In: Opt. Laser Technol., vol. 147, no. 107696, pp. None, 2022.
Abstract | Tags: Colorimetric change, Fabry-P{é}rot interferometer, Multiparameter sensing, Optical fiber sensor, Relative humidity, Respiration
@article{Liu2022-fh,
title = {A single-film fiber optical sensor for simultaneous measurement
of carbon dioxide and relative humidity},
author = {Liangliang Liu and Stephen P Morgan and Ricardo Correia and Serhiy Korposh},
year = {2022},
date = {2022-03-01},
journal = {Opt. Laser Technol.},
volume = {147},
number = {107696},
pages = {None},
publisher = {Elsevier BV},
abstract = {Colorimetric measurement is a versatile, low-cost method for
bio-/chemical sensing and that has importance in biomedical
applications. General carbon dioxide (CO2) sensors based on
colorimetric change of a pH indicator report only one parameter
at a time and are cross-sensitive to relative humidity (RH).
This work describes a novel optical fiber sensor with a thin
film on the distal end of the fiber, combining colorimetric
measurement and a white light Fabry-P\'{e}rot interferometer
(FPI) for the simultaneous measurement of CO2 and RH. The CO2
sensitive dye ion-pair: thymol blue and tetramethylammonium
hydroxide are encapsulated inside organically modified silica
forming an extrinsic FPI cavity (refractive index of 1.501 $±$
0.02 and thickness of 5.83 $±$ 0.09 μm). The sensor
reversibly responds to 0-6% CO2 and 0-90% RH with negligible
cross-sensitivity and allows measurement of both parameters
simultaneously. A sensitivity of ∼0.19 nm/%RH is obtained for
RH measurement based on the wavelength shift of the FPI and
there is a polynomial correlation between the average intensity
of selected wavelengths and the concentration of CO2. The
applicability of the sensor is demonstrated by measuring the CO2
and RH exhaled from human breath with a percent error of 3.1%
and 2.2% respectively compared to a commercial datalogger. A
simulation model is provided for the dye-encapsulated FPI sensor
allowing simulation of spectra of sensors with different film
thicknesses.},
keywords = {Colorimetric change, Fabry-P{\'{e}}rot interferometer, Multiparameter sensing, Optical fiber sensor, Relative humidity, Respiration},